Create tie trunk to the Centralized Messaging Server

Procedure

  1. Enter add trunk-group 6.

  2. Enter a value for:
    • Group Type

    • Group Name

    • TAC

    • Carrier Medium

    • Dial Access?

    • Service Type

    • Member Assignment Method

    • Signaling Group

    • (Since the signaling group is not defined at this stage of configuration, you need to revisit this SAT screen and assign the signaling group after you create the signaling group)

    • Number of Members

  3. Go to page 2 of 21 of the trunk-group screens.

  4. Enter a value for:
    • Supplementary Service Protocol

    • Format

  5. Go to page 3 of 21 of the trunk-group screens.

  6. Enter a value for:
    • NCA-TSC Trunk Member

    • Send Name

    • Send Calling Number

  7. Enter change node-names ip.

  8. Enter a value for:
    • Name

    • IP Address

  9. Enter add signaling-group 6.

  10. Enter a value for:
    • Group Type

    • Max number of NCA TSC

    • Max number of CA TSC

    • Trunk Group for NCA TSC

    • Trunk Group for Channel Selection

    • TSC Supplementary Service Protocol

    • Near-end Node Name

    • Far-end Node Name

    • Far-end Listen Port

    • Far-end Network Region